China Standard CHINAMFG factory oil free rotary Screw air compressor with CE and ISO air compressor oil

Product Description

Industrial Silent/Mute Medical Dry Oil Free Oilless Direct Drive Rotary Double Screw Type Air Compressor Advantages

1.Clean air 100% oil-free, class 0 oil free air according to ISO8537-1  
 
2.Adopt GHH air end made in Germany
 
3.Technology patent used in oil free compressed air system
 
4.Significant energy saving, environmental-friendly and pollution-free
 
5.Low operation and maintenance cost
 
6.Powerful MAM microcomputer controller and touch screen
 
7.Designed especially for medical, pharmacy, instrument, coating, chemical industry and food processing, etc. 

DENAIR Dry Type Oil Free Screw Air Compressor In Hannover Messe 2017
 

DENAIR Class 0 Certification

Comparison between dry oil free compressor and lubricated screw air compressor

Dry Type Oil-free Air Compressor Technical Parameters

Model Maximum working pressure Capacity(FAD)* Installed
motor
power
Cooling Method Noise Level** Dimensions
(mm)
Weight Air  Outlet Pipe Diameter
50 Hz 60 Hz
bar(e) psig m³/min cfm m³/min cfm kW hp dB(A) L W H kG
DWW-55 7 102 9.35 330 8.06 285 55 75 Air Cooling W-water Cooling 74 2000 1200 1650 1900 G1-1/2″
8 116 9.17 324 8.04 284 55 75 74 2000 1200 1650 1900 G1-1/2″
10 145 8.11 286 7.05 249 55 75 74 2000 1200 1650 1900 G1-1/2″
DWW-55W 7 102 9.35 330 8.06 285 55 75 74 2000 1200 1650 1800 G1-1/2″
8 116 9.17 324 8.04 284 55 75 74 2000 1200 1650 1800 G1-1/2″
10 145 8.11 286 7.05 249 55 75 74 2000 1200 1650 1800 G1-1/2″
DWW-75 7 102 12.71 449 11.56 408 75 100 74 2000 1200 1650 2100 DN50
8 116 11.78 416 11.53 407 75 100 74 2000 1200 1650 2100 DN50
10 145 11.57 409 10.11 357 75 100 74 2000 1200 1650 2100 DN50
DWW-75W 7 102 12.71 449 11.56 408 75 100 74 2000 1200 1650 2000 DN50
8 116 11.78 416 11.53 407 75 100 74 2000 1200 1650 2000 DN50
10 145 11.57 409 10.11 357 75 100 74 2000 1200 1650 2000 DN50
DWW-90 7 102 14.6 515 13.61 480 90 120 76 2800 1800 1860 2800 DN50
8 116 14.32 506 13.47 476 90 120 76 2800 1800 1860 2800 DN50
10 145 13.55 478 12.5 441 90 120 76 2800 1800 1860 2800 DN50
DWW-90W 7 102 14.6 515 13.61 480 90 120 76 2800 1800 1860 2180 DN50
8 116 14.32 506 13.47 476 90 120 76 2800 1800 1860 2180 DN50
10 145 13.55 478 12.5 441 90 120 76 2800 1800 1860 2180 DN50
DWW-110 7 102 20.27 716 N/A*** N/A*** 110 150 78 2800 1800 1860 3200 DN65
8 116 19.03 672 N/A*** N/A*** 110 150 78 2800 1800 1860 3200 DN65
10 145 16.65 588 15.57 550 110 150 78 2800 1800 1860 3200 DN65
DWW-110W 7 102 20.27 716 N/A*** N/A*** 110 150 78 2800 1800 1860 3050 DN65
8 116 19.03 672 N/A*** N/A*** 110 150 78 2800 1800 1860 3050 DN65
10 145 16.65 588 15.57 550 110 150 78 2800 1800 1860 3050 DN65
DWW-132 7 102 23.94 845 20.09 709 132 175 78 2800 1800 1860 3340 DN65
8 116 22.47 793 19.87 702 132 175 78 2800 1800 1860 3340 DN65
10 145 20.19 713 N/A*** N/A*** 132 175 78 2800 1800 1860 3340 DN65
DWW-132W 7 102 23.94 845 20.48 723 132 175 78 2800 1800 1860 3170 DN65
8 116 22.47 793 20.26 715 132 175 78 2800 1800 1860 3170 DN65
10 145 20.19 713 19.82 700 132 175 78 2800 1800 1860 3170 DN65
DWW-160 7 102 27.26 962 25.47 899 160 215 78 2800 1800 1860 3700 DN65
8 116 25.86 913 25.17 889 160 215 78 2800 1800 1860 3700 DN65
10 145 23.87 843 23.18 819 160 215 78 2800 1800 1860 3700 DN65
DWW-160W 7 102 27.26 962 25.47 899 160 215 78 2800 1800 1860 3300 DN65
8 116 25.86 913 25.17 889 160 215 78 2800 1800 1860 3300 DN65
10 145 23.87 843 23.8 819 160 215 78 2800 1800 1860 3300 DN65
DWW-185 7 102 30.19 1066 28.88 1571 185 250 78 2800 1800 1860 3900 DN65
8 116 29.53 1043 28.3 999 185 250 78 2800 1800 1860 3900 DN65
10 145 27.2 960 27.17 960 185 250 78 2800 1800 1860 3900 DN65
DWW-185W 7 102 30.19 1066 28.88 1571 185 250 78 2800 1800 1860 3460 DN65
8 116 29.53 1043 28.3 999 185 250 78 2800 1800 1860 3460 DN65
10 145 27.2 960 27.17 960 185 250 78 2800 1800 1860 3460 DN65
DWW-200W 7 102 36.41 1286 31.14 1100 200 270 78 3100 2150 2200 4300 DN100
8 116 33.86 1196 30.52 1078 200 270 78 3100 2150 2200 4300 DN100
10 145 30.35 1071 28.82 1018 200 270 78 3100 2150 2200 4300 DN100
DWW-220W 7 102 38.99 1377 37.54 1325 220 300 78 3100 2150 2200 4500 DN100
8 116 37.93 1339 36.78 1299 220 300 78 3100 2150 2200 4500 DN100
10 145 33.79 1193 31.08 1097 220 300 78 3100 2150 2200 4500 DN100
DWW-250W 7 102 47.26 1669 41.53 1466 250 350 78 3100 2150 2200 4550 DN100
8 116 43.31 1529 40.69 1437 250 350 78 3100 2150 2200 4550 DN100
10 145 38.88 1373 37.43 1322 250 350 78 3100 2150 2200 4550 DN100
DWW-280W 7 102 51.04 1802 N/A*** N/A*** 280 375 80 3400 2400 2200 4800 DN100
8 116 47.24 1668 N/A*** N/A*** 280 375 80 3400 2400 2200 4800 DN100
10 145 43.26 1528 41.4 1462 280 375 80 3400 2400 2200 4800 DN100
DWW-315W 7 102 52.03 1837 N/A*** N/A*** 315 425 80 3400 2400 2200 5000 DN100
8 116 51.04 1802 N/A*** N/A*** 315 425 80 3400 2400 2200 5000 DN100
10 145 47.18 1666 N/A*** N/A*** 315 425 80 3400 2400 2200 5000 DN100

Low Pressure Dry Type Oil-free Air Compressor Technical Parameters

Model Maximum working pressure Capacity(FAD)* Installed
motor
power
Cooling Method Noise Level** Dimensions
(mm)
Weight Air
Outlet Pipe Diameter
50 Hz 60 Hz
bar(e) psig m³/min cfm m³/min cfm kW hp dB(A) L W H kG
DWL-55-2 2.5 37 15.33 541 14.4 508 55 75 Air Cooling W-water Cooling 69 2100 1500 1790 2500 DN100
DWL-55-3 3.5 51 12.78 451 10.85 383 55 75 69 2100 1500 1790 2500 DN100
DWL-75-2 2.5 37 19.92 703 19.85 701 75 100 69 2100 1500 1790 2650 DN100
DWL-75-3 3.5 51 16.3 575 15.86 560 75 100 69 2100 1500 1790 2650 DN100
DWL-90-2 2.5 37 26.07 921 26.28 928 90 120 72 2800 1800 1860 2750 DN100
DWL-90-3 3.5 51 19.54 690 18.3 646 90 120 72 2100 1500 1790 2750 DN100
DWL-110(W)-2 2.5 37 33.16 1171 29.82 1053 110 150 72 3100 2150 2200 3500 DN150
DWL-110(W)-3 3.5 51 25.6 904 23.9 884 110 150 72 2800 1800 1860 3000 DN150
DWL-132(W)-2 2.5 37 40.24 1421 36.99 1271 132 175 72 3100 2150 2200 3600 DN150
DWL-132(W)-3 3.5 51 27.23 961 29.43 1039 132 175 72 2800 1800 1860 3100 DN150
DWL-160(W)-2 2.5 37 49.42 1745 45.2 1596 160 215 76 3100 2150 2200 3900 DN150
DWL-160(W)-3 3.5 51 35.75 1262 35.12 1240 160 215 76 3100 2150 2200 3800 DN150
DWL-185(W)-2 2.5 37 56.02 1989 52.71 1861 185 250 79 3400 2400 2200 4100 DN150
DWL-185(W)-3 3.5 51 42.21 1490 40.28 1422 185 250 79 3400 2400 2200 4000 DN150

*) FAD in accordance with ISO 1217 : 2009, Annex C: Absolute intake pressure 1 bar (a), cooling and air intake temperature 20 °C
**) Noise level as per ISO 2151 and the basic standard ISO 9614-2, operation at maximum operating pressure and maximum speed; tolerance: ± 3 dB(A)
***) TBD-To Be Discussed
****) W-Water cooling

DENAIR Factory

Why Choose DENAIR ?
1.Original Germany AERZEN/DENAIR air end,larger air delivery,lower noise.

2. Oil free screw air compressor Pass CE, ISO9001 Quality Certification

3. One of 3 biggest air compressor manufacturer in China

4. Complete before-on-after sales service

5. Immediate reply or solution by email or call
6.Special oil gas separator with patents

7.High efficiency motor, up to 96%

FAQ

Q1: Are you factory or trade company?  
A1: We are factory.

Q2: What the exactly address of your factory? 
A2: Our company is located in No. 6767, Tingfeng Rd. Xihu (West Lake) Dis.n District, ZheJiang  201502, China
And our factory is located in No. 366, YangzhuangBang Street, Pingxing Rd., Xindai Town, HangZhou, ZHangZhoug Province, China  

Q3: Warranty terms of your machine? 
A3: Two years warranty for the machine and technical support according to your needs.

Q4: Will you provide some spare parts of the machines? 
A4: Yes, of course.

Q5: How long will you take to arrange production? 
A5: 380V 50HZ we can delivery the goods within 10 days. Other electricity or other color we will delivery within 22 days

Q6: Can you accept OEM orders? 
A6: Yes, with professional design team, OEM orders are highly welcome

  /* October 22, 2571 15:47:17 */(()=>{function d(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

air compressor

What Are the Key Components of a Water-Lubrication System in Compressors?

A water-lubrication system in compressors typically consists of several key components that work together to provide lubrication and cooling to the compressor. Here’s a detailed explanation of the key components of a water-lubrication system in compressors:

Water Supply:

  • Water Source: The water-lubrication system requires a water source that provides clean and suitable water for lubrication. The water can be sourced from various places such as municipal water supply, well water, or treated water from a dedicated water treatment system.
  • Water Inlet: The water inlet is the entry point where water enters the compressor’s lubrication system. It may include valves, filters, or other components to regulate and control the water flow.

Lubrication System:

  • Water Jackets: Water jackets are channels or passages built into the compressor’s housing or cylinder walls. These jackets allow water to circulate and come into direct contact with the compressor’s moving parts, providing lubrication and cooling. The water jackets help dissipate heat generated during compression and prevent excessive temperatures that could damage the compressor.
  • Water Pump: The water pump is responsible for circulating water through the water jackets and the entire lubrication system. It provides the necessary pressure to ensure adequate water flow and distribution to the compressor’s components.
  • Flow Control Devices: Flow control devices, such as valves or flow restrictors, are often included in the water-lubrication system to regulate and control the water flow rate. These devices help maintain optimal water pressure and flow throughout the system, ensuring effective lubrication and cooling.
  • Water Filters: Water filters are used to remove impurities, sediment, or debris from the water before it enters the lubrication system. They help prevent blockages, protect the compressor’s components from damage, and maintain the quality of the water used for lubrication.
  • Water Separator: A water separator is a component that removes excess water, moisture, or condensate from the compressed air. It ensures that the compressed air leaving the compressor is dry and free from excess water content, preventing potential issues such as corrosion or contamination downstream.

Control and Monitoring:

  • Temperature Sensors: Temperature sensors are used to monitor the temperature of the water and the compressor components. They provide feedback to the control system, allowing for adjustments in water flow or cooling measures if required to maintain optimal operating conditions.
  • Pressure Sensors: Pressure sensors are employed to monitor the water pressure within the lubrication system. They help ensure that the water flow and pressure are within the desired range, allowing for proper lubrication and cooling of the compressor.
  • Control System: A control system, which may include a combination of sensors, valves, and controllers, is responsible for regulating and maintaining the operation of the water-lubrication system. It can monitor various parameters, such as temperature, pressure, and flow, and make adjustments as needed to ensure efficient and safe operation.

Regular maintenance, inspection, and monitoring of the key components of the water-lubrication system are essential to ensure its proper functioning and to prevent any issues that could affect the performance and longevity of the compressor.

air compressor

Are There Any Restrictions on the Type of Water Used in Water-Lubricated Compressors?

When it comes to water-lubricated compressors, there are certain restrictions and considerations regarding the type of water that can be used. Here’s a detailed explanation of the restrictions on the type of water used in water-lubricated compressors:

Water Quality:

  • Cleanliness: The water used in water-lubricated compressors should be clean and free from excessive impurities or contaminants. Impurities like sediment, minerals, or debris can cause blockages, wear, or damage to the compressor components. It is important to use water that meets the cleanliness requirements specified by the manufacturer.
  • Chemical Composition: The chemical composition of the water can also be a factor to consider. Water with high mineral content or hardness can lead to scale formation, which can affect the performance and lifespan of the compressor. Water treatment methods, such as water softening or filtration, may be necessary to maintain the desired water quality.

Water Temperature:

  • Freezing Point: In cold climates, it is important to ensure that the water used in the compressor’s lubrication system does not freeze. Freezing can cause operational issues and damage to the equipment. The water temperature should be maintained above freezing point through insulation, heating, or other suitable methods.
  • Temperature Range: Water-lubricated compressors may have specific temperature requirements to ensure optimal operation and lubrication. Operating the compressor with water temperatures outside the recommended range can affect its performance and lifespan. It is important to adhere to the manufacturer’s guidelines regarding the acceptable temperature range for the water used.

Water Treatment:

  • Water Treatment Systems: Depending on the quality of the available water supply, it may be necessary to use water treatment systems to ensure the water meets the required standards. Water treatment systems can help remove impurities, control chemical composition, and maintain the desired water quality for effective lubrication and cooling.
  • Water Treatment Frequency: Regular maintenance and monitoring of the water treatment systems are essential to ensure their effectiveness. The frequency of water treatment, such as filtration or chemical treatment, may vary depending on the specific conditions and the water quality in the area.

Manufacturer Recommendations:

  • Consulting the Manufacturer: It is important to consult the manufacturer’s guidelines and recommendations regarding the type of water to be used in water-lubricated compressors. Manufacturers may specify the acceptable water quality parameters, treatment methods, or restrictions to ensure optimal performance and longevity of the compressor.

By considering the cleanliness, chemical composition, temperature, and appropriate water treatment measures, the type of water used in water-lubricated compressors can be optimized to meet the requirements specified by the manufacturer. Adhering to these restrictions helps ensure efficient and reliable operation of the compressor while minimizing the risk of component damage or performance issues.

air compressor

Are Water-Lubricated Air Compressors Suitable for Food and Beverage Industries?

Water-lubricated air compressors can be highly suitable for the food and beverage industries due to several reasons:

  1. Food-grade lubrication: Water is a natural and food-grade lubricant. It does not introduce harmful contaminants or chemicals into the production process, ensuring the safety and quality of food and beverage products. Water lubrication eliminates the risk of oil contamination in food products that can occur with oil-lubricated compressors.
  2. Compliance with hygiene standards: The food and beverage industries have strict hygiene standards and regulations. Water-lubricated air compressors align with these standards as water is a clean and sanitary lubricant. It minimizes the risk of cross-contamination and helps maintain a hygienic production environment.
  3. Reduced risk of product contamination: Water lubrication eliminates the possibility of oil carryover or oil vapor entering the compressed air system. This reduces the risk of oil contamination in food and beverage products, ensuring their purity and quality.
  4. Improved product shelf life: Oil-lubricated compressors can release oil aerosols or vapors that may negatively affect the taste, odor, or quality of food and beverage products. Water-lubricated compressors eliminate this concern, contributing to improved product shelf life and maintaining the desired sensory attributes.
  5. Easy cleanup and maintenance: Water lubrication simplifies cleanup and maintenance procedures in food and beverage production facilities. Water does not leave behind sticky residues or require extensive cleaning processes. It facilitates faster and more efficient cleaning, reducing downtime and improving overall productivity.
  6. Environmental friendliness: Water is a sustainable and environmentally friendly lubricant choice. It is non-toxic, biodegradable, and does not contribute to air or water pollution. Using water-lubricated air compressors aligns with the sustainability goals of the food and beverage industries.

Considering these factors, water-lubricated air compressors are well-suited for the food and beverage industries, ensuring compliance with hygiene standards, preventing product contamination, and promoting a safe and sustainable production environment.

water_lubrication_air_compressorwater_lubrication_air_compressor
editor by lmc 2025-02-24